Difference between revisions of "GUFI updates"

From BESIII Ferrara Group Wiki
Jump to: navigation, search
 
(4 intermediate revisions by the same user not shown)
Line 18: Line 18:
 
* Scrollbar in acquisition window working!
 
* Scrollbar in acquisition window working!
 
* Updated TP load from configuration
 
* Updated TP load from configuration
 +
 +
=== GUFI V2.3 ===
 +
* Reskin
 +
* More use of tabs, only the first one now is needed for "standard users"
 +
* In acquisition, added a button to enable o disable restart
 +
* Big work on the fitting in the noise measure tool
 +
* Imported TP settings from the calibration dictionary
 +
* Add the possibility to add quickly specific setting for a certain TIGER. Now used for TP settings. Syntax ex.: 
 +
<nowiki>#Possible commands are ADD and SET 
 +
#Comments line begin with "#" 
 +
#Command GEMROC TIGER FIELD value 
 +
ADD 0 5 TP_Vcal_ref 1</nowiki>
 +
* Longer TD acquisition time
 +
* Tab to display GEMROC firmware and IVT reading
 +
* Tab with advanced threshold settings, up to now:
 +
** An easy place to set the thresholds
 +
** Calculate the threshold position in fC (care, the baseline position is not always well determined, measure for noisy chip not precise)
 +
* Added message fields also in the "command" section (but still not in use)
 +
 +
=== GUFI V.3.0 ===
 +
* B3CLK_sim on master disabled  by default
 +
* More time before timeout, PMT-off raised to 1500V
 +
* Added the possibility to load old settings form conf_log
 +
* Add soft TP launch button
 +
* Generic scans to scan any TIGER parameter
 +
*Automatically disabled the on run analysys at subrun stop.
 +
*Saving the GEMROC errors at acquisition stop.
 +
*Improved noise fit performance
 +
 +
=== GUFI V.3.2 ===
 +
 +
*Rate interface finalized and fixed
 +
*Rate equalization testable
 +
*Fast thr scan to characterize FEB L 3
 +
*Acquisition problems solved
 +
 +
=== GUFI V.3.3 ===
 +
 +
*Tools for acquisition monitor and notification

Latest revision as of 05:55, 18 January 2020

This page will shows the release notes for the new GUFI versions, starting from the 2.1.

The last release can be downloaded here:

https://github.com/bortalberto/TIGER_scripts/releases

GUFI V2.1[edit | edit source]

  • Improved single scan fit visualization in threshold scan
  • New data format in acquisition: RUN_$run number$/SubRUN_$sub run number$_GEMROC_$gemroc number$_$mode TL or TM$.dat for data and similar for logs.
  • Added configuration log containing all the configuration parameters for GEMROC, TIGER and channel for each acquisition subrun
  • Improved the fit on the baseline after the threshold scan, making it more robust:
    • If the fit doesn't converge or the median value is above 63, the median value will be set at first value of threshold above 1000 and the sigma at 1
    • Loading the fit, if the fit product sigma*number of sigmas is below 1, it will be set at 1.
    • This should solve problems of high count rate from channels with very low noise
  • Implemented function to load the TP values from the calibration (button in "noise measure too" window)
  • Now to start the TP from the GEMROC one only need to click on "Start TP" in the "noise measure tool "window

GUFI V2.2[edit | edit source]

  • Scrollbar in acquisition window working!
  • Updated TP load from configuration

GUFI V2.3[edit | edit source]

  • Reskin
  • More use of tabs, only the first one now is needed for "standard users"
  • In acquisition, added a button to enable o disable restart
  • Big work on the fitting in the noise measure tool
  • Imported TP settings from the calibration dictionary
  • Add the possibility to add quickly specific setting for a certain TIGER. Now used for TP settings. Syntax ex.:

#Possible commands are ADD and SET #Comments line begin with "#" #Command GEMROC TIGER FIELD value ADD 0 5 TP_Vcal_ref 1

  • Longer TD acquisition time
  • Tab to display GEMROC firmware and IVT reading
  • Tab with advanced threshold settings, up to now:
    • An easy place to set the thresholds
    • Calculate the threshold position in fC (care, the baseline position is not always well determined, measure for noisy chip not precise)
  • Added message fields also in the "command" section (but still not in use)

GUFI V.3.0[edit | edit source]

  • B3CLK_sim on master disabled by default
  • More time before timeout, PMT-off raised to 1500V
  • Added the possibility to load old settings form conf_log
  • Add soft TP launch button
  • Generic scans to scan any TIGER parameter
  • Automatically disabled the on run analysys at subrun stop.
  • Saving the GEMROC errors at acquisition stop.
  • Improved noise fit performance

GUFI V.3.2[edit | edit source]

  • Rate interface finalized and fixed
  • Rate equalization testable
  • Fast thr scan to characterize FEB L 3
  • Acquisition problems solved

GUFI V.3.3[edit | edit source]

  • Tools for acquisition monitor and notification