GUFI updates
This page will shows the release notes for the new GUFI versions, starting from the 2.1.
The last release can be downloaded here:
https://github.com/bortalberto/TIGER_scripts/releases
GUFI V2.1[edit | edit source]
- Improved single scan fit visualization in threshold scan
- New data format in acquisition: RUN_$run number$/SubRUN_$sub run number$_GEMROC_$gemroc number$_$mode TL or TM$.dat for data and similar for logs.
- Added configuration log containing all the configuration parameters for GEMROC, TIGER and channel for each acquisition subrun
- Improved the fit on the baseline after the threshold scan, making it more robust:
- If the fit doesn't converge or the median value is above 63, the median value will be set at first value of threshold above 1000 and the sigma at 1
- Loading the fit, if the fit product sigma*number of sigmas is below 1, it will be set at 1.
- This should solve problems of high count rate from channels with very low noise
- Implemented function to load the TP values from the calibration (button in "noise measure too" window)
- Now to start the TP from the GEMROC one only need to click on "Start TP" in the "noise measure tool "window
GUFI V2.2[edit | edit source]
- Scrollbar in acquisition window working!
- Updated TP load from configuration
GUFI V2.3[edit | edit source]
- Reskin
- More use of tabs, only the first one now is needed for "standard users"
- In acquisition, added a button to enable o disable restart
- Big work on the fitting in the noise measure tool
- Imported TP settings from the calibration dictionary
- Add the possibility to add quickly specific setting for a certain TIGER. Now used for TP settings. Syntax ex.:
#Possible commands are ADD and SET #Comments line begin with "#" #Command GEMROC TIGER FIELD value ADD 0 5 TP_Vcal_ref 1
- Longer TD acquisition time
- Tab to display GEMROC firmware and IVT reading
- Tab with advanced threshold settings, up to now:
- An easy place to set the thresholds
- Calculate the threshold position in fC (care, the baseline position is not always well determined, measure for noisy chip not precise)
- Added message fields also in the "command" section (but still not in use)
GUFI V.3.0[edit | edit source]
- B3CLK_sim on master disabled by default
- More time before timeout, PMT-off raised to 1500V
- Added the possibility to load old settings form conf_log
- Add soft TP launch button
- Generic scans to scan any TIGER parameter
- Automatically disabled the on run analysys at subrun stop.
- Saving the GEMROC errors at acquisition stop.
- Improved noise fit performance
GUFI V.3.2[edit | edit source]
- Rate interface finalized and fixed
- Rate equalization testable
- Fast thr scan to characterize FEB L 3
- Acquisition problems solved
GUFI V.3.3[edit | edit source]
- Tools for acquisition monitor and notification