Difference between revisions of "GUFI updates"
(Created page with "This page will shows the release notes for the new GUFI versions, starting from the 2.3. The last release can be downloaded here: https://github.com/bortalberto/TIGER_scripts") (Tag: Visual edit) |
|||
(6 intermediate revisions by the same user not shown) | |||
Line 1: | Line 1: | ||
− | This page will shows the release notes for the new GUFI versions, starting from the 2. | + | This page will shows the release notes for the new GUFI versions, starting from the 2.1. |
The last release can be downloaded here: | The last release can be downloaded here: | ||
− | https://github.com/bortalberto/TIGER_scripts | + | https://github.com/bortalberto/TIGER_scripts/releases |
+ | |||
+ | === GUFI V2.1 === | ||
+ | * Improved single scan fit visualization in threshold scan | ||
+ | * New data format in acquisition: ''RUN_$run number$/SubRUN_$sub run number$_GEMROC_$gemroc number$_$mode TL or TM$.dat'' for data and similar for logs. | ||
+ | * Added configuration log containing all the configuration parameters for GEMROC, TIGER and channel for each acquisition subrun | ||
+ | * Improved the fit on the baseline after the threshold scan, making it more robust: | ||
+ | ** If the fit doesn't converge or the median value is above 63, the median value will be set at first value of threshold above 1000 and the sigma at 1 | ||
+ | ** Loading the fit, if the fit product sigma*number of sigmas is below 1, it will be set at 1. | ||
+ | ** This should solve problems of high count rate from channels with very low noise | ||
+ | * Implemented function to load the TP values from the calibration (button in "''noise measure too"'' window) | ||
+ | * Now to start the TP from the GEMROC one only need to click on "Start TP" in the "''noise measure tool "''window | ||
+ | === GUFI V2.2 === | ||
+ | * Scrollbar in acquisition window working! | ||
+ | * Updated TP load from configuration | ||
+ | |||
+ | === GUFI V2.3 === | ||
+ | * Reskin | ||
+ | * More use of tabs, only the first one now is needed for "standard users" | ||
+ | * In acquisition, added a button to enable o disable restart | ||
+ | * Big work on the fitting in the noise measure tool | ||
+ | * Imported TP settings from the calibration dictionary | ||
+ | * Add the possibility to add quickly specific setting for a certain TIGER. Now used for TP settings. Syntax ex.: | ||
+ | <nowiki>#Possible commands are ADD and SET | ||
+ | #Comments line begin with "#" | ||
+ | #Command GEMROC TIGER FIELD value | ||
+ | ADD 0 5 TP_Vcal_ref 1</nowiki> | ||
+ | * Longer TD acquisition time | ||
+ | * Tab to display GEMROC firmware and IVT reading | ||
+ | * Tab with advanced threshold settings, up to now: | ||
+ | ** An easy place to set the thresholds | ||
+ | ** Calculate the threshold position in fC (care, the baseline position is not always well determined, measure for noisy chip not precise) | ||
+ | * Added message fields also in the "command" section (but still not in use) | ||
+ | |||
+ | === GUFI V.3.0 === | ||
+ | * B3CLK_sim on master disabled by default | ||
+ | * More time before timeout, PMT-off raised to 1500V | ||
+ | * Added the possibility to load old settings form conf_log | ||
+ | * Add soft TP launch button | ||
+ | * Generic scans to scan any TIGER parameter | ||
+ | *Automatically disabled the on run analysys at subrun stop. | ||
+ | *Saving the GEMROC errors at acquisition stop. | ||
+ | *Improved noise fit performance | ||
+ | |||
+ | === GUFI V.3.2 === | ||
+ | |||
+ | *Rate interface finalized and fixed | ||
+ | *Rate equalization testable | ||
+ | *Fast thr scan to characterize FEB L 3 | ||
+ | *Acquisition problems solved | ||
+ | |||
+ | === GUFI V.3.3 === | ||
+ | |||
+ | *Tools for acquisition monitor and notification |
Latest revision as of 05:55, 18 January 2020
This page will shows the release notes for the new GUFI versions, starting from the 2.1.
The last release can be downloaded here:
https://github.com/bortalberto/TIGER_scripts/releases
GUFI V2.1[edit | edit source]
- Improved single scan fit visualization in threshold scan
- New data format in acquisition: RUN_$run number$/SubRUN_$sub run number$_GEMROC_$gemroc number$_$mode TL or TM$.dat for data and similar for logs.
- Added configuration log containing all the configuration parameters for GEMROC, TIGER and channel for each acquisition subrun
- Improved the fit on the baseline after the threshold scan, making it more robust:
- If the fit doesn't converge or the median value is above 63, the median value will be set at first value of threshold above 1000 and the sigma at 1
- Loading the fit, if the fit product sigma*number of sigmas is below 1, it will be set at 1.
- This should solve problems of high count rate from channels with very low noise
- Implemented function to load the TP values from the calibration (button in "noise measure too" window)
- Now to start the TP from the GEMROC one only need to click on "Start TP" in the "noise measure tool "window
GUFI V2.2[edit | edit source]
- Scrollbar in acquisition window working!
- Updated TP load from configuration
GUFI V2.3[edit | edit source]
- Reskin
- More use of tabs, only the first one now is needed for "standard users"
- In acquisition, added a button to enable o disable restart
- Big work on the fitting in the noise measure tool
- Imported TP settings from the calibration dictionary
- Add the possibility to add quickly specific setting for a certain TIGER. Now used for TP settings. Syntax ex.:
#Possible commands are ADD and SET #Comments line begin with "#" #Command GEMROC TIGER FIELD value ADD 0 5 TP_Vcal_ref 1
- Longer TD acquisition time
- Tab to display GEMROC firmware and IVT reading
- Tab with advanced threshold settings, up to now:
- An easy place to set the thresholds
- Calculate the threshold position in fC (care, the baseline position is not always well determined, measure for noisy chip not precise)
- Added message fields also in the "command" section (but still not in use)
GUFI V.3.0[edit | edit source]
- B3CLK_sim on master disabled by default
- More time before timeout, PMT-off raised to 1500V
- Added the possibility to load old settings form conf_log
- Add soft TP launch button
- Generic scans to scan any TIGER parameter
- Automatically disabled the on run analysys at subrun stop.
- Saving the GEMROC errors at acquisition stop.
- Improved noise fit performance
GUFI V.3.2[edit | edit source]
- Rate interface finalized and fixed
- Rate equalization testable
- Fast thr scan to characterize FEB L 3
- Acquisition problems solved
GUFI V.3.3[edit | edit source]
- Tools for acquisition monitor and notification