Difference between revisions of "FEB list"

From BESIII Ferrara Group Wiki
Jump to: navigation, search
m (Spare FEBs ranking)
m (Spare FEBs ranking)
Line 567: Line 567:
 
=== Spare FEBs ranking ===
 
=== Spare FEBs ranking ===
  
* 5: 1 dead channel
+
# 49
* 49
+
# 53
* 53
+
# 55
* 55
+
# 58
* 58
+
# 5: 1 dead channel
  
 
== Layer 3 ==
 
== Layer 3 ==

Revision as of 04:00, 27 October 2019

Here the status of all FEBs is reported.

Calibration files for each chip can be found at the following link:

https://github.com/fabio-cossio/TIGER

Layer 1[edit | edit source]

Current number of good FEBs = 22/16

L1 anode-FEB connector pinout

HW_FEB list[edit | edit source]

HW_FEB Status Chip 1 Chip 2 Notes
1 Torino 1 2 broken connector
2 to be installed on nL1 1 2 IHEP
3 back to Torino 1 2
4 to be installed on nL1 1 2 Going to IHEP
5 to be installed on nL1 1 2 IHEP
6 back to Torino 1 2 missing calibration files
7 Torino 1 2 broken ESD protection diode
8 SPARE 1 2 IHEP
9 SPARE 1 2 IHEP (Tx align when tilted?)
10 to be installed on nL1 1 2 IHEP (old TB calibration)
11 installed on oL1 1 2
12 Torino 1 2 leakage
13 SPARE 1 2 IHEP
14 installed on oL1 1 2
15 1 2 missing
16 SPARE 1 2 IHEP
17 installed on oL1 1 2
18 back to Torino 1 2
19 to be installed on nL1 1 2 Going to IHEP
20 installed on oL1 1 2 old TB calibration
21 to be installed on nL1 1 2 IHEP
22 to be installed on nL1 1 2 IHEP
23 back to Torino 1 2
24 to be installed on nL1 1 2 Going to IHEP
25 to be installed on nL1 1 2 IHEP
26 to be installed on nL1 1 2 IHEP
27 to be installed on nL1 1 2 IHEP
28 SPARE 1 2 Going to IHEP
29 to be installed on nL1 1 2 IHEP
30 to be installed on nL1 1 2 IHEP
31 Torino 1 2
32 to be installed on nL1 1 2 Going to IHEP
33 SPARE 1 2 Going to IHEP
34 to be installed on nL1 1 2 Going to IHEP
35 Torino 1 2
61 to be installed on nL1 1 2 Going to IHEP (old production)
New production starting from FEB 26 (10 FEBs --> FEB26-35)

Spare FEBs ranking[edit | edit source]

  1. FEB13: no dead channels
  2. FEB33: 1 dead channel
  3. FEB8: 1 dead channel
  4. FEB16: 1 dead channel
  5. FEB28: 2 dead channels
  6. FEB9: 2 dead channels + Tx align issues when tilted

Layer 2[edit | edit source]

Current number of good FEBs = 33/28

L2 anode-FEB connector pinout

HW_FEB list[edit | edit source]

HW_FEB Status Chip 1 Chip 2 Notes
1 installed on L2 1 2 old TB calibration
2 installed on L2 1 2 old TB calibration
3 installed on L2 1 2
4 installed on L2 1 2
5 SPARE 1 2 Going to IHEP
6 installed on L2 1 2
7 installed on L2 1 2
8 Torino 1 2 spare? already calibrated
9 installed on L2 1 2
10 AEMME 1 2
11 removed from L2 (Sep 2019) 1 2 high noise and dead channels
12 installed on L2 1 2
13 Torino 1 2
14 Torino 1 2
15 Torino 1 2 spare? already calibrated
16 Torino 1 2
17 installed on L2 1 2
18 installed on L2 1 2
19 installed on L2 1 2
20 installed on L2 1 2
21 installed on L2 1 2
22 Torino 1 2
23 Torino 1 2
24 installed on L2 1 2
25 installed on L2 1 2
26 installed on L2 1 2
27 installed on L2 1 2
28 1 2 missing
29 removed from L2 (Sep 2019) 1 2 missing TP on chip 1
30 installed on L2 1 2
31 Torino 1 2
32 installed on L2 1 2
33 installed on L2 1 2
34 installed on L2 1 2
35 Torino 1 2
36 installed on L2 1 2
37 installed on L2 1 2
38 installed on L2 1 2
39 Torino 1 2
49 SPARE 1 2 Going to IHEP
50 installed on L2 1 2 installed on Sep 2019
51 Torino 1 2
52 installed on L2 1 2
53 SPARE 1 2 IHEP
54 Torino 1 2
55 SPARE 1 2 IHEP
56 installed on L2 1 2 installed on Sep 2019
57 installed on L2 1 2 installed on Sep 2019
58 SPARE 1 2 Going to IHEP

Spare FEBs ranking[edit | edit source]

  1. 49
  2. 53
  3. 55
  4. 58
  5. 5: 1 dead channel

Layer 3[edit | edit source]

Current number of good FEBs = 32/36

L3 anode-FEB connector pinout

HW_FEB list[edit | edit source]

HW_FEB Status Chip 1 Chip 2 Notes
1 NOT OK (2 old dead channels + config and 8/10b errors) 1 2 IHEP (in)
2 OK (1 old dead channel) 1 2 IHEP (in)
3 OK 1 2 IHEP (in)
4 OK 1 2 IHEP (in)
5 OK 1 2 IHEP (in)
6 AEMME 1 2
7 NOT OK (config errors) 1 2 IHEP (in)
8 NOT OK (2 noisy channels) 1 2 IHEP (out)
9 OK 1 2 IHEP (planar)
10 OK 1 2 IHEP (in)
11 Torino 1 2
12 OK 1 2 IHEP (in)
13 OK 1 2 IHEP (spare)
14 Angelo 1 2
15 OK 1 2 IHEP (out)
16 NOT OK (2 dead channels, 1 old + 1 new) 1 2 IHEP (in)
17 OK 1 2 IHEP (out)
18 OK 1 2 IHEP (in)
19 OK 1 2 IHEP (spare)
20 NOT OK (2 noisy channels) 1 2 IHEP (out)
21 OK 1 2 IHEP (spare)
22 OK 1 2 IHEP (in)
23 OK 1 2 IHEP (in)
24 OK 1 2 IHEP (in)
25 OK 1 2 IHEP (spare)
26 OK 1 2 IHEP (planar)
27 OK 1 2 IHEP (out)
28 OK 1 2 IHEP (planar)
29 OK 1 2 IHEP (planar)
30 OK 1 2 IHEP (in)
31 NOT OK (8/10b errors) 1 2 IHEP (out)
32? OK 1 2 IHEP (planar)
33 OK 1 2 IHEP (out)
34 Torino 1 2
35 Torino 1 2
36 maybe OK (old dead channel is alive) 1 2 IHEP (planar)
37 OK 1 2 IHEP (out)
38 Torino 1 2
39 OK (1 "dead" channel) 1 2 IHEP (in)
40 OK 1 2 IHEP (out)
41 OK 1 2 IHEP (in)
42 NOT OK (1 new dead, old dead is alive) 1 2 IHEP (in)
43 Torino 1 2
44 OK 1 2 IHEP (out)
45 OK 1 2 IHEP (out)
46 Torino 1 2
47 OK 1 2 IHEP (in)
48 OK 1 2 IHEP (spare)
49 NOT OK (3 new dead channels) 1 2 IHEP (out)
50 Torino 1 2
51 Angelo 1 2
52 Angelo 1 2
53 Torino 1 2
54 Torino 1 2
55 Torino 1 2
56 1 2
57 1 2
58 1 2
59 1 2
FEBs currently used to readout planar GEMs were installed on L3 "out side"