FEB list
Here the status of all FEBs is reported.
Calibration files for each chip can be found at the following link:
https://github.com/fabio-cossio/TIGER
Contents
Layer 1[edit | edit source]
Current number of good FEBs = 20/16
HW_FEB list[edit | edit source]
HW_FEB | Status | Chip 1 | Chip 2 | Notes |
---|---|---|---|---|
1 | Torino | 1 | 2 | broken connector |
2 | installed on L1 | 1 | 2 | IHEP (in) |
3 | back to Torino | 1 | 2 | |
4 | installed on L1 | 1 | 2 | IHEP (out) |
5 | installed on L1 | 1 | 2 | IHEP (in) |
6 | back to Torino | 1 | 2 | missing calibration files |
7 | Torino | 1 | 2 | broken ESD protection diode |
8 | Torino | 1 | 2 | 1 dead channel (chip 1)
+ config errors (chip 2) |
9 | IHEP | 1 | 2 | SPARE (Tx align when tilted?) |
10 | installed on L1 | 1 | 2 | IHEP (in) (old TB calibration) |
11 | left on oL1 | 1 | 2 | |
12 | Torino | 1 | 2 | leakage |
13 | IHEP | 1 | 2 | broken ESD protection diodes and Res
repaired, SPARE |
14 | left on oL1 | 1 | 2 | |
15 | 1 | 2 | missing | |
16 | IHEP | 1 | 2 | SPARE |
17 | left on oL1 | 1 | 2 | |
18 | back to Torino | 1 | 2 | |
19 | installed on L1 | 1 | 2 | IHEP (out) |
20 | left on oL1 | 1 | 2 | old TB calibration |
21 | installed on L1 | 1 | 2 | IHEP (in) |
22 | installed on L1 | 1 | 2 | IHEP (out) |
23 | back to Torino | 1 | 2 | |
24 | installed on L1 | 1 | 2 | IHEP (out) |
25 | installed on L1 | 1 | 2 | IHEP (in) |
26 | installed on L1 | 1 | 2 | IHEP (out) |
27 | installed on L1 | 1 | 2 | IHEP (out) |
28 | IHEP | 1 | 2 | SPARE |
29 | installed on L1 | 1 | 2 | IHEP (in) |
30 | installed on L1 | 1 | 2 | IHEP (out) |
31 | Torino | 1 | 2 | |
32 | installed on L1 | 1 | 2 | IHEP (out) |
33 | Torino | 1 | 2 | 1 dead channel (chip 1)
+ config errors (chip 2) |
34 | installed on L1 | 1 | 2 | IHEP (in) |
35 | Torino | 1 | 2 | |
61 | installed on L1 | 1 | 2 | IHEP (in)(old production) |
New production starting from FEB 26 (10 FEBs --> FEB26-35)
Spare FEBs ranking[edit | edit source]
OLD[edit | edit source]
FEB10: no dead channels (old TB calibration)- FEB13: no dead channels (repaired ESD protection circuit components)
- FEB16: 1 dead channel
- FEB28: 2 dead channels
- FEB9: 2 dead channels + Tx align issues when tilted
FEB33: 1 dead channel (chip 2 config errors) --> DO NOT USEFEB8: 1 dead channel (chip 2 config errors) --> DO NOT USE
JULY 2023[edit | edit source]
- FEB38: no dead channels
- FEB41: no dead channels
- FEB42: no dead channels
FEBM[edit | edit source]
- FEBM5: no dead channels
- FEBM2: no dead channels
- FEBM7: 1 dead channel
- FEBM4: 1 dead channel
- FEBM1: 1 dead channel
- FEBM6: 1 dead channel
- FEBM8: 1 dead channel
- FEBM3: 1 dead channel
Layer 2[edit | edit source]
Current number of good FEBs = 32/28
HW_FEB list[edit | edit source]
HW_FEB | Status | Chip 1 | Chip 2 | Notes |
---|---|---|---|---|
1 | installed on L2 | 1 | 2 | old TB calibration |
2 | installed on L2 | 1 | 2 | old TB calibration |
3 | installed on L2 | 1 | 2 | |
4 | installed on L2 | 1 | 2 | |
5 | IHEP | 1 | 2 | SPARE |
6 | installed on L2 | 1 | 2 | |
7 | installed on L2 | 1 | 2 | |
8 | Torino | 1 | 2 | spare? already calibrated |
9 | installed on L2 | 1 | 2 | |
10 | AEMME | 1 | 2 | |
11 | Torino | 1 | 2 | removed from L2 (Sep 2019)
high noise and dead channels |
12 | installed on L2 | 1 | 2 | |
13 | Torino | 1 | 2 | |
14 | Torino | 1 | 2 | |
15 | Torino | 1 | 2 | spare? already calibrated |
16 | Torino | 1 | 2 | |
17 | installed on L2 | 1 | 2 | |
18 | installed on L2 | 1 | 2 | |
19 | installed on L2 | 1 | 2 | |
20 | installed on L2 | 1 | 2 | |
21 | installed on L2 | 1 | 2 | |
22 | Torino | 1 | 2 | |
23 | Torino | 1 | 2 | |
24 | installed on L2 | 1 | 2 | |
25 | installed on L2 | 1 | 2 | |
26 | installed on L2 | 1 | 2 | |
27 | installed on L2 | 1 | 2 | |
28 | IHEP | 1 | 2 | DAQ debug tests |
29 | Torino | 1 | 2 | removed from L2 (Sep 2019)
missing TP on chip 1 |
30 | installed on L2 | 1 | 2 | |
31 | Torino | 1 | 2 | |
32 | installed on L2 | 1 | 2 | |
33 | installed on L2 | 1 | 2 | |
34 | Torino | 1 | 2 | removed from L2 (November 2019)
chip dead due to water leakage |
35 | Ferrara (Angelo) | 1 | 2 | ch.30 dead on chip 1 |
36 | installed on L2 | 1 | 2 | |
37 | installed on L2 | 1 | 2 | |
38 | installed on L2 | 1 | 2 | |
39 | Torino | 1 | 2 | |
49 | installed on L2 | 1 | 2 | installed on Nov 2019 |
50 | installed on L2 | 1 | 2 | installed on Sep 2019 |
51 | Torino | 1 | 2 | |
52 | installed on L2 | 1 | 2 | |
53 | installed on L2 | 1 | 2 | installed on Nov 2019 |
54 | Torino | 1 | 2 | |
55 | IHEP | 1 | 2 | SPARE |
56 | installed on L2 | 1 | 2 | installed on Sep 2019 |
57 | IHEP | 1 | 2 | installed on Sep 2019,
removed on Nov 2019 good SPARE! |
58 | IHEP | 1 | 2 | SPARE |
Spare FEBs ranking[edit | edit source]
OLD[edit | edit source]
FEB57: no dead channelsFEB55: no dead channelsFEB58: no dead channels- FEB5: 1 dead channel
NEW[edit | edit source]
FEB70: no dead channelsFEB54: no dead channelsFEB61: no dead channelsFEB62: no dead channelsFEB66: no dead channelsFEB64: no dead channelsFEB71: 1 dead channelFEB69: 1 dead channelFEB72: 1 dead channelFEB65: 1 dead channel- FEB67: 2 dead channels
OTHER[edit | edit source]
FEB31: no dead channelsFEB15: no dead channels- FEB8: no dead channels
FEB63: no dead channelsFEB59: no dead channels
JULY 2023[edit | edit source]
- FEB74: no dead channels
- FEB51: no dead channels
- FEB77: no dead channels
- FEB78: 1 dead channel
- FEB79: 2 dead channels
- FEB76: 2 dead channels
- FEB73: 3 dead channels
Layer 3[edit | edit source]
Current number of good FEBs = 38/36
HW_FEB list[edit | edit source]
HW_FEB | Status | Chip 1 | Chip 2 | Notes |
---|---|---|---|---|
1 | Torino | 1 | 2 | NOT OK (2 old dead channels
+ config and 8/10b errors) |
2 | IHEP | 1 | 2 | OK (1 old dead channel) |
3 | IHEP | 1 | 2 | OK |
4 | 1 | 2 | ||
5 | Ferrara (planar) | 1 | 2 | OK (planar) |
6 | AEMME | 1 | 2 | |
7 | Torino | 1 | 2 | NOT OK (config errors) |
8 | Ferrara (planar) | 1 | 2 | NOT OK (2 noisy channels)
OK (noisy channels solved, planar) |
9 | Ferrara (planar) | 1 | 2 | OK (planar) |
10 | 1 | 2 | Dead due to water leakage in Ferrara (02.12.2020) | |
11 | Torino | 1 | 2 | |
12 | Ferrara (planar) | 1 | 2 | OK (planar) |
13 | Ferrara (planar) | 1 | 2 | OK (planar) |
14 | Ferrara (Angelo) | 1 | 2 | |
15 | IHEP | 1 | 2 | OK |
16 | Ferrara (GEM discharges) | 1 | 2 | NOT OK (2 dead channels, 1 old + 1 new) |
17 | IHEP | 1 | 2 | OK |
18 | IHEP | 1 | 2 | OK |
19 | IHEP | 1 | 2 | OK |
20 | IHEP | 1 | 2 | OK |
21 | IHEP | 1 | 2 | OK |
22 | IHEP | 1 | 2 | OK |
23 | IHEP | 1 | 2 | OK |
24 | IHEP | 1 | 2 | OK |
25 | IHEP | 1 | 2 | OK |
26 | Ferrara (planar) | 1 | 2 | OK (planar) |
27 | IHEP | 1 | 2 | OK |
28 | 1 | 2 | chip 2 had damaged bonding while on Ferrara planar setup | |
29 | Ferrara (planar) | 1 | 2 | OK (planar) |
30 | IHEP | 1 | 2 | OK |
31 | Torino | 1 | 2 | NOT OK (8/10b errors due to damaged bonds) |
32 | Ferrara (planar) | 1 | 2 | OK (planar) |
33 | IHEP | 1 | 2 | OK |
34 | Torino | 1 | 2 | |
35 | IHEP | 1 | 2 | OK |
36 | IHEP | 1 | 2 | OK (1 dead channel) |
37 | IHEP | 1 | 2 | OK |
38 | Torino | 1 | 2 | |
39 | IHEP | 1 | 2 | OK (1 "dead" channel --> stuck Efine) |
40 | IHEP | 1 | 2 | OK |
41 | IHEP | 1 | 2 | OK |
42 | Ferrara (Angelo) | 1 | 2 | NOT OK (1 new dead, old dead is alive) |
43 | Torino | 1 | 2 | |
44 | IHEP | 1 | 2 | OK |
45 | IHEP | 1 | 2 | OK |
46 | Torino | 1 | 2 | |
47 | IHEP | 1 | 2 | OK |
48 | IHEP | 1 | 2 | OK |
49 | Ferrara (GEM discharges) | 1 | 2 | NOT OK (3 new dead channels) |
50 | Torino | 1 | 2 | |
51 | Ferrara (Angelo) | 1 | 2 | |
52 | Ferrara (Angelo) | 1 | 2 | |
53 | Torino (TB spare) | 1 | 2 | OK (chip 2 has 1 dead channel) |
54 | Torino | 1 | 2 | |
55 | IHEP | 1 | 2 | OK (1 "dead" channel --> stuck Efine) |
56 | IHEP | 1 | 2 | OK |
57 | IHEP | 1 | 2 | OK |
58 | Torino (TB spare) | 1 | 2 | OK |
59 | Torino | 1 | 2 | |
60 | Torino | 1 | 2 |
FEBs currently used to readout planar GEMs were installed on L3 "out side"