Mapping

From BESIII Ferrara Group Wiki
Jump to: navigation, search

Geometry[edit | edit source]

  1. The old position of the FEB on top of the detectors: File:Mapping FEB update 190619.pdf
  2. An update version of the FEB position: File:Mapping FEB 080120.pdf
  3. The updated version matching the CGEMBOSS strips order: File:20200330 FEB L1 L2.pdf
  4. The updated version matching the CGEMBOSS strips order and with correct WEST/EAST sides: File:20200513 mapping.pdf

Channels not used[edit | edit source]

The following channels are not connected to any strip because the correspondent FEB is connected to the last connector of the anode foil

  • FEB_label=0, chip 2 --> ch. 3,4,11,22 (X-side) 41,43,45,47,54 (V-side)
  • FEB_label=8, chip 1 --> ch. 0,16,38,42 (X-side) 8,10,21,45,47,57 (V-side)
  • FEB_label=36, chip 1 --> ch. 57 (V-side)
  • FEB_label=43, chip 1 --> ch. 57 (V-side)

GEMROCs history[edit | edit source]

  • GEMROC 10 was replaced on 18.08.2019 due to the missing reset signals for 2 FEBs: after this replacement the issue was solved.

FEBs history[edit | edit source]

FEBs replacements during 2019 May's integration week:

  • GEMROC 4, TIGER 2 and 3: HW_FEB = 8 --> HW_FEB = 17
  • GEMROC 4, TIGER 4 and 5: HW_FEB = 7 --> HW_FEB = 18
  • GEMROC 6, TIGER 4 and 5: HW_FEB = 39 --> HW_FEB = 5 (No TP on T5)
  • GEMROC 7, TIGER 4 and 5: HW_FEB = 23 --> HW_FEB = 52 (No good TD values)
  • GEMROC 9, TIGER 6 and 7: HW_FEB = 14 --> HW_FEB = 7 (Can't configure T7)


FEBs left on oL1 for the Experimental Hall Test in September 2019:


FEBs replacements during 2019 September (10.09.2019):

  • GEMROC 6, TIGER 4 and 5 (FEB_label 26): HW_FEB = 5 (49*) --> HW_FEB = 50 (old FEB had missing calibration due to wrong HW label, chip 1, chip 2)
  • GEMROC 8, TIGER 6 and 7 (FEB_label 35): HW_FEB = 29 --> HW_FEB = 56 (missing TP on chip 1)
  • GEMROC 9, TIGER 2 and 3 (FEB_label 37): HW_FEB = 11 --> HW_FEB = 57 (several noisy and dead channels on chip 1 and chip 2)
* actually on the chips side it was not HW_FEB = 5, but HW_FEB = 49 --> this explains the missing/wrong calibration


FEBs replaced on L2 in November 2019:

  • GEMROC 5, TIGER 6 and 7 (FEB_label 23): HW_FEB = 34 --> 53 (dead chip due to water leakage, chip 1, chip 2)
  • GEMROC 9, TIGER 2 and 3 (FEB_label 37): HW_FEB = 57 --> 49 (some holes in the stripX 1-45, chip 1, chip 2)

FEB/TIGER issues[edit | edit source]

The following FEB or TIGER are currently disabled or have some issues:

GEMROC 8 - FEB 2 (TIGER 4-5, FEB_label = 34)

  • WHEN: mid March, RUN 376-377
  • WHAT: unstable analogue VDD on TIGER 5, propagated also to other chip of same FEB (TIGER 4) and then also the whole CAEN channel
  • ACTION: cable disconnected on 23/06/2020 due to overcurrent on CAEN channel to preserve other FEBs of the same LV channel


GEMROC 9 - TIGER 0 (FEB_label = 36, chip 1)

  • WHEN: 12/05/2020, RUN 405
  • WHAT: chip does not configure


GEMROC 0 - FEB 2 (TIGER 4-5, FEB_label = 2)

  • WHEN: 29/05/2020, RUN 408
  • WHAT: missing analogue current (IA)
  • WHY: aVDD ok up to DLVPC, since no current is absorbed by the FEB the issue may be in the short-haul cable not properly connected to the FEB (aVDD is the first wire of the cable and so it is more prone to break)


GEMROC 8 - FEB 0 (TIGER 0-1, FEB_label = 32)

  • WHEN: 29/05/2020, RUN 408
  • WHAT: missing analogue current (IA)
  • WHY: aVDD ok up to DLVPC, since no current is absorbed by the FEB the issue may be in the short-haul cable not properly connected to the FEB (aVDD is the first wire of the cable and so it is more prone to break)


GEMROC 10 - FEB 2 (TIGER 4-5, FEB_label = 42)

  • WHEN: 16/09/2020, NO ACQUISITION (start from post-summer RUNs)
  • WHAT: chip does configure, but the absorbed current (both analogue and digital) and FEB temperature show strange values and behaviour
  • WHY: to be investigated, from data (RUN 418-420) TIGER 85 seems ok, while TIGER 84 is almost with no data
  • UPDATE: on 04/08/2021 chips do not configure anymore


GEMROC 10 - TIGER 7 (FEB_label = 43)

  • WHEN: 22/09/2020, NO ACQUISITION (start from post-summer RUNs)
  • WHAT: chip does not configure, the other chip on the same FEB is OK (dead after 3 days)
  • WHY: a drop of water cooling system was spotted on this FEB, may be the cause of this issue


GEMROC 10 - TIGER 6 (FEB_label = 43)

  • WHEN: 25/09/2020, NO ACQUISITION (start from post-summer RUNs)
  • WHAT: chip does not configure, the other chip on the same FEB had the same issue 3 days ago
  • WHY: a drop of water cooling system was spotted on this FEB, may be the cause of this issue


GEMROC 2 - TIGER 4

  • WHEN: 04/08/2021
  • WHAT: chip does not configure, the other chip on the same FEB is OK


GEMROC 7 - TIGER 3

  • WHEN: 28/09/2021
  • WHAT: chip does not configure, different values at every register read


GEMROC 5 - TIGER 1

  • WHEN: 28/09/2021
  • WHAT: chip does not configure, read values are all 0


GEMROC 7 - TIGER 7

  • WHEN: 22/11/2021
  • WHAT: Time delay scan not ok


GEMROC 4 - FEB 2 (TIGER 4-5)

  • WHEN: 17/01/2022
  • WHAT: Analogue current almost 0, channels not responding properly (TIGER 4 seems ok, TIGER 5 has no hits)
  • WHEN: 22/03/2022
  • WHAT: chips do not configure


GEMROC 10 - FEB 1 (TIGER 2-3)

  • WHEN: 17/01/2022
  • WHAT: Errors on temperature read --> FEB is kept ON, disable automatic turning OFF (TIGER 2 seems ok, TIGER 3 has no hits)
  • WHY: maybe APT 1000 sensor read errors


GEMROC 1 - FEB 3

  • WHEN: 22/03/2022
  • WHAT: Analogue current almost 0, no baseline found in threshold scan


GEMROC 4 - FEB 3 (TIGER 6-7)

  • WHEN: 04/11/2022
  • WHAT: chip does not configure, read values are all 0

Known issues[edit | edit source]

  • 8b10b errors on GEMROC 7 TIGER 0-1


Layer 1[edit | edit source]

L1 FEB pinout

GEMROC 0[edit | edit source]

GEMROC 0
FEB_label TIGER HW_FEB Chip BESIII ID Notes
0 0 61 1 0
0 1 61 2 1
1 2 5 1 2
1 3 5 2 3
2 4 38 1 4 was FEB2
2 5 38 2 5 was FEB2
3 6 21 1 6
3 7 21 2 7

GEMROC 1[edit | edit source]

GEMROC 1
FEB_label TIGER HW_FEB Chip BESIII ID Notes
4 0 25 1 8
4 1 25 2 9
5 2 10 1 10
5 3 10 2 11
6 4 36 1 12 was FEB29
6 5 36 2 13 was FEB29
7 6 34 1 14
7 7 34 2 15

GEMROC 2[edit | edit source]

GEMROC 2
FEB_label TIGER HW_FEB Chip BESIII ID Notes
8 0 32 1 16
8 1 32 2 17
9 2 28 1 18 was FEB26
9 3 28 2 19 was FEB26
10 4 41 1 20 was FEB27
10 5 41 2 21 was FEB27
11 6 22 1 22
11 7 22 2 23

GEMROC 3[edit | edit source]

GEMROC 3
FEB_label TIGER HW_FEB Chip BESIII ID Notes
12 0 24 1 24
12 1 24 2 25
13 2 4 1 26
13 3 4 2 27
14 4 42 1 28 was FEB19
14 5 42 2 29 was FEB19
15 6 30 1 30
15 7 30 2 31

Layer 2[edit | edit source]

For Layer 2 channels 61, 62 and 63 are not connected to any strip, hence they should be disabled and not be considered.

L2 FEB pinout

GEMROC 4[edit | edit source]

GEMROC 4
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
16 0 31 1 32 24/07/18
16 1 31 2 33 24/07/18
17 2 33 1 34 23/07/18
17 3 33 2 35 23/07/18
18 4 69 1 36 installed on Feb 2023
18 5 69 2 37 installed on Feb 2023
19 6 55 1 38 installed on Feb 2023
19 7 55 2 39 installed on Feb 2023

GEMROC 5[edit | edit source]

GEMROC 5
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
20 0 57 1 40 installed on Feb 2023
20 1 57 2 41 installed on Feb 2023
21 2 17 1 42 16/07/18
21 3 17 2 43 16/07/18
22 4 4 1 44 was FEB38 (installed on Feb 2023)
22 5 4 2 45 was FEB38 (installed on Feb 2023)

GEMROC 6[edit | edit source]

GEMROC 6
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
23 0 72 1 46 23/05/19 installed on Nov 2019
23 1 72 2 47 23/05/19 installed on Nov 2019
24 2 2 1 48 23/07/18
24 3 2 2 49 23/07/18
25 4 1 1 50 installed on Feb 2023
25 5 1 2 51 installed on Feb 2023
26 6 50 1 52 22/05/19 installed on Sep 2019
26 7 50 2 53 22/05/19 installed on Sep 2019

GEMROC 7[edit | edit source]

GEMROC 7
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
27 0 62 1 54 2017
27 1 62 2 55 2017
28 2 37 1 56 2017
28 3 37 2 57 2017
29 4 53 1 58 installed on Feb 2023
29 5 53 2 59 installed on Feb 2023

GEMROC 8[edit | edit source]

GEMROC 8
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
30 0 61 1 60 installed on Feb 2023
30 1 61 2 61 installed on Feb 2023
31 2 56 1 62 installed on Feb 2023
31 3 56 2 63 installed on Feb 2023
32 4 59 1 64 installed on Feb 2023
32 5 59 2 65 installed on Feb 2023
33 6 15 1 66 installed on Feb 2023
33 7 15 2 67 installed on Feb 2023

GEMROC 9[edit | edit source]

GEMROC 9
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
34 0 63 1 68 installed on Feb 2023
34 1 63 2 69 installed on Feb 2023
35 2 58 1 70 23/05/19 installed on Sep 2019
35 3 58 2 71 23/05/19 installed on Sep 2019
36 4 65 1 72 installed on Feb 2023
36 5 65 2 73 installed on Feb 2023

GEMROC 10[edit | edit source]

GEMROC 10 was replaced on 18.08.2019 due to the missing reset signals for 2 FEBs: after this replacement the issue was solved.

GEMROC 10
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
37 0 71 1 74 15/10/19 installed on Nov 2019, holes in the stripX still present
37 1 71 2 75 15/10/19 installed on Nov 2019, holes in the stripX still present
38 2 54 1 76 installed on Feb 2023
38 3 54 2 77 installed on Feb 2023
39 4 64 1 78 installed on Feb 2023
39 5 64 2 79 installed on Feb 2023
40 6 20 1 80 16/07/18
40 7 20 2 81 16/07/18

GEMROC 11[edit | edit source]

GEMROC 11
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
41 0 70 1 82 installed on Feb 2023
41 1 70 2 83 installed on Feb 2023
42 2 66 1 84 installed on Feb 2023
42 3 66 2 85 installed on Feb 2023
43 4 49 1 86 installed on Feb 2023
43 5 49 2 87 installed on Feb 2023

Layer 3[edit | edit source]

For Layer 3 channels 62 and 63 are not connected to any strip, hence they should be disabled and not be considered.

L3 FEB pinout


GEMROC 12[edit | edit source]

GEMROC 12
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
44 0 27 1 88
44 1 27 2 89
45 2 81 1 90
45 3 81 2 91
46 4 57 1 92
46 5 57 2 93
47 6 58 1 94
47 7 58 2 95

GEMROC 13[edit | edit source]

GEMROC 13
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
48 0 54 1 96
48 1 54 2 97
49 2 77 1 98
49 3 77 2 99
50 4 39 1 100
50 5 39 2 101
51 6 25 1 102
51 7 25 2 103

GEMROC 14[edit | edit source]

GEMROC 14
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
52 0 61 1 104
52 1 61 2 105
53 2 55 1 106
53 3 55 2 107
54 4 80 1 108
54 5 80 2 109
55 6 22 1 110
55 7 22 2 111

GEMROC 15[edit | edit source]

GEMROC 15
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
56 0 37 1 112
56 1 37 2 113
57 2 62 1 114
57 3 62 2 115
58 4 70 1 116
58 5 70 2 117
59 6 48 1 118
59 7 48 2 119

GEMROC 16[edit | edit source]

GEMROC 16
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
60 0 69 1 120
60 1 69 2 121
61 2 59 1 122
61 3 59 2 123
* Switch detector side after FEB 61

GEMROC 17[edit | edit source]

GEMROC 17
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
62 0 64 1 124
62 1 64 2 125
63 2 35 1 126
63 3 35 2 127
64 4 79 1 128
64 5 79 2 129
65 6 21 1 130
65 7 21 2 131

GEMROC 18[edit | edit source]

GEMROC 18
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
66 0 18 1 132
66 1 18 2 133
67 2 44 1 134
67 3 44 2 135
68 4 78 1 136
68 5 78 2 137
69 6 65 1 138
69 7 65 2 139

GEMROC 19[edit | edit source]

GEMROC 19
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
70 0 74 1 140
70 1 74 2 141
71 2 20 1 142
71 3 20 2 143
72 4 40 1 144
72 5 40 2 145
73 6 75 1 146
73 7 75 2 147

GEMROC 20[edit | edit source]

GEMROC 20
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
74 0 17 1 148
74 1 17 2 149
75 2 47 1 150
75 3 47 2 151
76 4 24 1 152
76 5 24 2 153
77 6 56 1 154
77 7 56 2 155

GEMROC 21[edit | edit source]

GEMROC 21
FEB_label TIGER HW_FEB Chip BESIII ID Cal. date Notes
78 0 19 1 156
78 1 19 2 157
79 2 45 1 158
79 3 45 2 159

Planar GEMs (OLD)[edit | edit source]

Old setup, not present anymore

GEMROC 12[edit | edit source]

GEMROC 12
FEB_label TIGER HW_FEB Chip BESIII ID Notes
48 0 32 1 96 planar MID (plane 1)
48 1 32 2 97 planar MID (plane 1)
49 2 10 1 98 planar MID (plane 1)
49 3 10 2 99 planar MID (plane 1)
50 4 empty 1 100
50 5 empty 2 101
51 6 empty 1 102
51 7 empty 2 103

GEMROC 13[edit | edit source]

GEMROC 13
FEB_label TIGER HW_FEB Chip BESIII ID Notes
52 0 9 1 104 planar BOT (plane 4)
52 1 9 2 105 planar BOT (plane 4)
53 2 28 1 106 planar BOT (plane 4)
53 3 28 2 107 planar BOT (plane 4)
54 4 26 1 108 planar TOP (plane 0)
54 5 26 2 109 planar TOP (plane 0)
55 6 29 1 110 planar TOP (plane 0)
55 7 29 2 111 planar TOP (plane 0)

Ferrara/Test Beam Setup[edit | edit source]

  • Planars 0-1 get HV from RIGHT distributor
  • Planars 2-3 get HV from LEFT distributor

GEMROC 0[edit | edit source]

GEMROC 0
FEB_label TIGER HW_FEB Chip BESIII ID Planar Notes
0 29 1 - planar 0 (stripX) swapped with HWFEB 9 at the start of testbeam (see note 2)
1 29 2 - planar 0 (stripX) swapped with HWFEB 9 at the start of testbeam (see note 2)
2 9 1 - planar 0 (stripY) swapped with HWFEB 29 at the start of testbeam (see note 2)
3 9 2 - planar 0 (stripY) swapped with HWFEB 29 at the start of testbeam (see note 2)
4 12 1 - planar 1 (stripX)
5 12 2 - planar 1 (stripX)
6 8 1 - planar 1 (stripY) mounted on 17 July 2021 (see note 3)
7 8 2 - planar 1 (stripY) mounted on 17 July 2021 (see note 3)

GEMROC 1[edit | edit source]

GEMROC 1
FEB_label TIGER HW_FEB Chip BESIII ID Planar Notes
0 5 1 - planar 2 (stripX)
1 5 2 - planar 2 (stripX)
2 32 1 - planar 2 (stripY)
3 32 2 - planar 2 (stripY)
4 13 1 - planar 3 (stripX) mounted on 22 June 2021 (see note 1)
5 13 2 - planar 3 (stripX) mounted on 22 June 2021 (see note 1)
6 26 1 - planar 3 (stripY)
7 26 2 - planar 3 (stripY)

Notes:

  1. L3 FEB28 Chip2 had damaged bonding on Sun 20 June 2021: the FEB has been replaced with L3 FEB13 on Tue 22 June 2021
  2. L3 FEB9 and L3 FEB29 (reading planar 0) were swapped at the start of July 2021 CERN test-beam: cosmic data from Ferrara setup has these two FEBs inverted
  3. L3 FEB4 had several dead channels during July 2021 CERN test-beam: L3 FEB4 has been replaced with L3 FEB8 on Sat 17 July 2021


Ferrara 2022[edit | edit source]

GEMROC 0[edit | edit source]

GEMROC 0
FEB_label TIGER HW_FEB Chip BESIII ID Planar Notes
0 47 1 - planar 0 (stripX)
1 47 2 - planar 0 (stripX)
2 22 1 - planar 0 (stripY)
3 22 2 - planar 0 (stripY)
4 41 1 - planar 1 (stripX)
5 41 2 - planar 1 (stripX)
6 15 1 - planar 1 (stripY)
7 15 2 - planar 1 (stripY)

GEMROC 1[edit | edit source]

GEMROC 1
FEB_label TIGER HW_FEB Chip BESIII ID Planar Notes
0 23 1 - planar 2 (stripX)
1 23 2 - planar 2 (stripX)
2 2 1 - planar 2 (stripY)
3 2 2 - planar 2 (stripY)
4 27 1 - planar 3 (stripX)
5 27 2 - planar 3 (stripX)
6 33 1 - planar 3 (stripY)
7 33 2 - planar 3 (stripY)