List of bug and problems[edit | edit source]
- The radius used on the L2 do not correspond to the real one
- µTPC disabled up to now
- Only 33% of the hits has a cluster on both sides of the L2, while in principle it should be 100% --> problem due to ROC?
- FEB from 0 to 15 are noisy at channel 62
- Peaking background on FEB=6 && channel = 62
Possible solutions to be confirmed[edit | edit source]
The charge measured with random trigger is above 10fC, up to 50 fC[edit | edit source]
This is due to few channels with very high noise:
- FEB_label = 21, chip 2, channel 3
- FEB_label = 23, chip 1, channel 26
- FEB_label = 36, chip 2, channel 3
- FEB_label = 43, chip 2, channel 45
3/4 of these channels (ch. 3 and 45) are located on the edge of the anode-FEB connector (see L2_FEB_pinout).
TO-DO:
- Check and confirm that removing these channels the very high charge noise disappears (for all runs)
- Check the FEB-anode connection
- Check the position of these FEBs --> are they close to some potential noise source?
Solved[edit | edit source]
- Charge decrease as the threshold increases -> due to some error in setting the threshold. Now if the thr_sigma*n_sigma < 1, threshold is increased by 1.
- The reconstruction is too slow with event.C -> lSolved by changing the arrays to vectors.
No signal from FEB 2 and 30[edit | edit source]
This is due to missing calibration files (raw data should be present):
- FEB 30 (calibration files available) has been restored
- FEB 2 (calibration files not available) will be provided soon with a temporary mock-up calibration (based on TP scan performed with GUFI)