Difference between revisions of "TIGER - GEMROC efficency"

From BESIII Ferrara Group Wiki
Jump to: navigation, search
(Analog test pulses on one channel)
(Blanked the page)
(Tags: Blanking, Visual edit)
 
(One intermediate revision by the same user not shown)
Line 1: Line 1:
== Triggerless efficiency ==
 
  
The triggerless efficency has ben measured with one TIGER and one GEMROC. The acquisition was set in triggerless mode and the TP are generated by the GEMROC itself. The GEMROC generate N TPs after each Frameworld received from the chip. The time between the TPs is set by another parameter. This parameter was set to make the TP emission homogeneous with respect to the time
 
 
=== Digital test pulses on 64 channels ===
 
{| class="wikitable"
 
|+
 
!TP per frameword
 
!Rate (kHz)
 
!Efficency
 
|-
 
|1
 
|4.8
 
|100%
 
|-
 
|2
 
|9.8
 
|100%
 
|-
 
|12
 
|58.6
 
|100%
 
|-
 
|13
 
|63.4
 
|98%
 
|}
 
 
=== Digital test pulses on one channel ===
 
{| class="wikitable"
 
!TP per frameword
 
!Rate (kHz)
 
!Efficency
 
|-
 
|20
 
|97.7
 
|100%
 
|-
 
|22
 
|107
 
|100%
 
|-
 
|25
 
|122
 
|100%
 
|-
 
|30
 
|146
 
|100%
 
|-
 
|35
 
|170
 
|100%
 
|-
 
|37
 
|180
 
|100%
 
|-
 
|40
 
|195
 
|90%
 
|}
 
 
=== Analog test pulses on one channel ===
 
{| class="wikitable"
 
!TP per frameword
 
!Rate (kHz)
 
!Efficency
 
|-
 
|10
 
|48.8
 
|100%
 
|-
 
|22
 
|107
 
|100%
 
|-
 
|25
 
|122
 
|100%
 
|-
 
|30
 
|146
 
|100%
 
|-
 
|37
 
|180
 
|100%
 
|-
 
|38
 
|185
 
|93%
 
|}
 

Latest revision as of 08:49, 31 May 2019